WARNING!
CONNECT TO POTABLE WATER SUPPLY.
This system is to be used for water only and
is not intended for use where water is microbiologically unsafe or with water of unknown quality
without adequate disinfection. System is designed for the supplemental bactericidal treatment of
public drinking water, or other drinking water, which has been tested and deemed acceptable for
human consumption by the water provider. The system is designed to reduce normally occurring
non-pathogenic or nuisance microorganisms only. System is not intended for treatment of
contaminated water.
WARNING!
TIP HAZARD.
Dispenser could tip or fall causing serious injury. Always install unit on a
firm, flat, and level surface and secure the
WL2FW Water Treatment System
to the base cabinet
with the screw provided to lock the components together. Secure unit to cabinet, wall, or floor if
needed. Never place heavy items on top of unit and never climb, stand, or hang on unit or storage
cabinet to prevent injury and damage.
WARNING!
UNIT IS HEAVY. TWO PERSON LIFT REQUIRED.
Transport unit empty and always use
material handling equipment or two people with proper lifting technique to reduce injury risk.
WARNING!
STORE AND TRANSPORT UNIT EMPTY. ALWAYS SANITIZE BEFORE USE.
The unit must be completely drained and sealed before storing to avoid stagnation and reduce
microbiological contamination (potential bacterial growth). Sanitize before use to eliminate any
potential microbiological contaminates
CAUTION!
INDOOR USE ONLY.
Intended for household use only. Never expose to direct sunlight,
heat sources, or ambient air temperature above 37°C (100°F) or below 2°C (35°F). Install indoors
and keep unit away from excessive humidity. Never expose to freezing temperatures. Ensure
there is adequate clearance around the unit (50mm minimum) to allow refrigeration system
condenser to dissipate heat. Warmer environments require more clearance around the unit.
Installs where the ambient temperature exceeds 27°C (80°F), require a minimum of 100mm
clearance for proper heat dissipation and efficient operation.
CAUTION!
USE A WATER PRESSURE REGULATOR.
Waterlogic will not be responsible for injury or
damage caused by excessive water pressure. Input or feed pressure must be 2.7Bar to 4Bar (2.7 to
4bar). Be aware of any potential pressure surges caused by building/municipal pumping stations.
Water block devices and external leak detectors are strongly recommended. Locate the unit as
close to the water supply and the electrical connections as possible to minimize risk.
CAUTION!
USE PROPER SUPPLY LINES AND FEED WITH POTABLE AMBIENT WATER ONLY.
Feed water over 37°C (100°F) may damage the treatment components. Always use supply lines
with adequate pressure rating and UV resistance. Close water supply valve and contact service
representative if a leak is noticed.
Contact Waterlogic for assistance or help finding an Authorized Service Representative.
Summary of Contents for WL2FL Free Standing
Page 14: ...WL2 FW Manual Page 14 Revision EU05 07 17 HEATER CIRCUIT HOT TANK WIRING...
Page 37: ...WL2 FW Manual Page 36 Revision EU05 07 17 WL2FW FLOW DIAGRAM COLD ONLY...
Page 38: ...WL2 FW Manual Page 37 Revision EU05 07 17 COLD AND AMBIENT...
Page 39: ...WL2 FW Manual Page 38 Revision EU05 07 17 HOT AND COLD...
Page 41: ...WL2 FW Manual Page 40 Revision EU05 07 17...
Page 42: ...WL2 FW Manual Page 41 Revision EU05 07 17 120V 60Hz Power Source 120V 60Hz 120V 60Hz...
Page 43: ...Power Source 120V 60Hz 120V 60Hz 120V 60Hz WL2 FW Manual Page 42 Revision EU05 07 17...