WL2 FW
Manual
Page 43 – Revision EU05-07-17
PRE-DELIVERY PROCEDURES
DANGER!
ELECTRICAL SHOCK HAZARD.
Only qualified personnel who have read and understand this entire manual should attempt to
install, or service this unit, failure to do so could result in death or serious injury. DO NOT plug
into an electrical supply until specifically instructed.
WARNING!
ALWAYS SANITIZE BEFORE USE.
Sanitize before use to eliminate any potential microbiological contaminates.
Materials Needed:
•
Personal Protective Equipment. Rubber or Nitrile Safety Gloves and Protective Eyewear
•
Phillips Screwdriver. Temperature Gauge.
•
Water Pitcher or Container to collect water from the faucet
•
3 Litre container or drain basin
•
Aquadosa Sanitizer – Or equivalent (5.25% Sodium Hypochlorite)
•
1/4”O.D. Plastic Tubing, at least 1.5m in length, and assorted 1/4” quick connect fittings.
•
Test Strips for measuring sanitizer levels
•
TDS Meter (Optional)
1.
Unpack the
Waterlogic WL2FW Water Treatment Systems
and check exterior for damage.
Sanitizing
Sanitize Aquadosa or other approved sanitizing cleaner throughout the cold and or ambient
circuits. Follow all instructions on the sanitizer and flush with fresh water through the faucet
until odour and taste is acceptable.
WARNING!
USE PROPER PERSONAL PROTECTIVE EQUIPMENT
Always ensure proper ventilation and use proper personal protective equipment such as gloves
and eye protection when using chemicals. Refer to Material Safety Data Sheet for specific
requirements of each chemical product. Take all necessary precautions to prevent sanitizer
from contacting eyes, clothing, and any other surfaces in could damage (carpets).
2.
We recommend using Aquadosa sanitizer, 60ml dose is enough to sanitize the machine. See
manufactures instructions for any other sanitizing solution used. Measure and insert 60ml
Aquadosa into the Sanitizing Cartridge. Always ensure sanitizer is compatible with stainless steel
and acetyl plastic.
3.
Connect sanitizing cartridge to inlet water supply and connect to inlet bulkhead fitting on back of
unit. Turn on water supply.
4.
Connect power to
WL2FW Water Treatment System
. DO NOT TURN ON RED
COMPRESSOR & HEATER SWITCH AT THIS TIME.
O=OFF
Summary of Contents for WL2FL Free Standing
Page 14: ...WL2 FW Manual Page 14 Revision EU05 07 17 HEATER CIRCUIT HOT TANK WIRING...
Page 37: ...WL2 FW Manual Page 36 Revision EU05 07 17 WL2FW FLOW DIAGRAM COLD ONLY...
Page 38: ...WL2 FW Manual Page 37 Revision EU05 07 17 COLD AND AMBIENT...
Page 39: ...WL2 FW Manual Page 38 Revision EU05 07 17 HOT AND COLD...
Page 41: ...WL2 FW Manual Page 40 Revision EU05 07 17...
Page 42: ...WL2 FW Manual Page 41 Revision EU05 07 17 120V 60Hz Power Source 120V 60Hz 120V 60Hz...
Page 43: ...Power Source 120V 60Hz 120V 60Hz 120V 60Hz WL2 FW Manual Page 42 Revision EU05 07 17...