WL2 FW
Manual
Page 62 – Revision EU05-07-17
8.
Hot Water Drip out of Faucet
Possible Reason
Solution
Small Outlet Vent Hole susceptible to scale
build up.
Descale Tank.
See Hot Tank Descaling Instructions that are included
further below in this Troubleshooting Section.
See instructional video on the Partner Area of the
Waterlogic.com website for more information.
All
Waterlogic
Hot Tanks have a built in Vent or
Expansion Chamber in the top of the tank except for
WL270 (GF) units.
The Vent Chamber allows for expansion of the water
when it is heated.
The chambers are separated by a welded-in tank
baffle.
Water always flows into the bottom of the Hot Tank
and out the top to the Faucet.
The Hot Tank Outlet Tube has a Restrictor in its base.
This ensures the reservoir is always full by allowing
more water in than out.
There is a small hole in the side of the Hot Tank Outlet
Tube that allows air and water to pass into the Vent
Chamber as it is heated.
Water in the Vent Chamber is suctioned back through
the Outlet Tube vent hole when water is dispensed.
Expansion of water as it is heated in the Reservoir will
push the water out the faucet when the outlet tube
vent hole becomes plugged with debris or scale.
The small Outlet Vent Hole is susceptible to scale build
up and is a key indicator that descaling is required.
It is critical to descale the Hot Tank through the vent
line and outlet line on a regular basis to prevent this
problem.
Descaling through the inlet and/or outlet lines only
will not clean the vent chamber and outlet vent hole
properly.
HOT TANK
HEATER
ELEMENT
THERMISTOR
WELL
OUTLET TUBE
INLET TUBE
EXPANSION
CHAMBER
EXPANSION SLIT
Summary of Contents for WL2FL Free Standing
Page 14: ...WL2 FW Manual Page 14 Revision EU05 07 17 HEATER CIRCUIT HOT TANK WIRING...
Page 37: ...WL2 FW Manual Page 36 Revision EU05 07 17 WL2FW FLOW DIAGRAM COLD ONLY...
Page 38: ...WL2 FW Manual Page 37 Revision EU05 07 17 COLD AND AMBIENT...
Page 39: ...WL2 FW Manual Page 38 Revision EU05 07 17 HOT AND COLD...
Page 41: ...WL2 FW Manual Page 40 Revision EU05 07 17...
Page 42: ...WL2 FW Manual Page 41 Revision EU05 07 17 120V 60Hz Power Source 120V 60Hz 120V 60Hz...
Page 43: ...Power Source 120V 60Hz 120V 60Hz 120V 60Hz WL2 FW Manual Page 42 Revision EU05 07 17...