WL2 FW
Manual
Page 46 – Revision EU05-07-17
19.
Connect power to
WL2FW Water Treatment System.
Compressor Test
20. Red Heater & Compressor to be in the on position
I=ON
. Always ensure tanks are
full of water before turning on the heater or the overheat (high limit) will open
and require manual reset. If the wire condenser at back of the unit is warm, the
refrigeration system is working.
I=ON
21.
Once the
WL2FW Water Treatment System
reaches its target temperature, the compressor will
shut off. Draw a glass of cold water and verify it is has chilled to proper temperature.
Heater Test
22.
Always ensure tanks are full of water before turning on the heater or the overheat (High Limit)
will open and require manual reset. It will take the heater approximately 10 minutes to heat the
water from ambient 24°C (75°F) to the factory set point of 87°C (187°F). Dispense a cup of hot
water to ensure the temperature/odour/taste is acceptable.
WARNING!
HOT WATER CAN BURN OR SCALD.
The
WL2FW Water Treatment System
produces Hot Water up to 87°C (187°F).
Water above 52°C (125°F) can cause severe burns or
scalding. Hot water should be dispensed carefully into insulated container to avoid injury.
Summary of Contents for WL2FL Free Standing
Page 14: ...WL2 FW Manual Page 14 Revision EU05 07 17 HEATER CIRCUIT HOT TANK WIRING...
Page 37: ...WL2 FW Manual Page 36 Revision EU05 07 17 WL2FW FLOW DIAGRAM COLD ONLY...
Page 38: ...WL2 FW Manual Page 37 Revision EU05 07 17 COLD AND AMBIENT...
Page 39: ...WL2 FW Manual Page 38 Revision EU05 07 17 HOT AND COLD...
Page 41: ...WL2 FW Manual Page 40 Revision EU05 07 17...
Page 42: ...WL2 FW Manual Page 41 Revision EU05 07 17 120V 60Hz Power Source 120V 60Hz 120V 60Hz...
Page 43: ...Power Source 120V 60Hz 120V 60Hz 120V 60Hz WL2 FW Manual Page 42 Revision EU05 07 17...