WL2 FW
Manual
Page 68 – Revision EU05-07-17
16.
Water Streams at an Angle
Solution
Rotate the Bung (Blue Silicone) and the JG fittings a few degrees.
Water Feed Pressure
Verify the Incoming Feed with a Pressure Regulator. Should be 2.7-
4bar, Use Pressure Regulator
The correct input water pressure is critical to the performance of the
unit to allow solenoids to open.
Outgoing Flow Rate
Verify the outgoing Flow Rate. Should be 1.89 Litres per minute (0.5
gallons per minute) - Firewall Purification.
Dispense water for one minute – should measure 1.89 Litres (0.5
gallons) per minute
Change Flow Restrictor if needed.