WL2 FW
Manual
Page 56 – Revision EU05-07-17
4.
Compressor is Not Running
Possible Reason
Solution
Red Heater & Compressor
Switch button on unit is in the
off position
Turn Red Heater & Compressor Switch on.
I = ON
Compressor Starting Circuit
Turn Red Heater & Compressor Switch off.
O = OFF.
Remove the compressor cap on side of the
compressor;
Disconnect the black and red terminal connectors;
Inspect the starter and overheat relay for any defects.
Replace components(s) as needed.
Turn Red Heater & Compressor Switch on
I = ON
and
retest compressor operation.