WL2 FW
Manual
Page 54 – Revision EU05-07-17
POWER TROUBLESHOOTING INDEX
1. Red Heater & Compressor Power Switch won't light and the Red LED on the Front
won't light
2. Red Heater & Compressor Power Switch is lit but the red LED on the Front is not lit
3. Compressor Runs but does Not Chill
4. Compressor is Not Running
1.
Red Heater and Compressor Power Switch won’t light and the Red LED on the
Front won’t light
Possible Reason
Solution
Circuit Breaker
Check the Circuit Breaker
Fuse is Blown
Replace Fuse
Defective / Loose Power Cord
Check that Power Cord is properly plugged in. If it is properly
plugged in, use a different power cord to verify.
Failed Socket - Power Line
Noise Filter, ElectroMagnetic
Interference filter (EMI)
Replace Socket - Power Line Noise Filter, ElectroMagnetic
Interference filter (EMI)
Defective Red Heater &
Compressor Switch
Replace Red Heater & Compressor Switch
Summary of Contents for WL2FL Free Standing
Page 14: ...WL2 FW Manual Page 14 Revision EU05 07 17 HEATER CIRCUIT HOT TANK WIRING...
Page 37: ...WL2 FW Manual Page 36 Revision EU05 07 17 WL2FW FLOW DIAGRAM COLD ONLY...
Page 38: ...WL2 FW Manual Page 37 Revision EU05 07 17 COLD AND AMBIENT...
Page 39: ...WL2 FW Manual Page 38 Revision EU05 07 17 HOT AND COLD...
Page 41: ...WL2 FW Manual Page 40 Revision EU05 07 17...
Page 42: ...WL2 FW Manual Page 41 Revision EU05 07 17 120V 60Hz Power Source 120V 60Hz 120V 60Hz...
Page 43: ...Power Source 120V 60Hz 120V 60Hz 120V 60Hz WL2 FW Manual Page 42 Revision EU05 07 17...