WL2 FW
Manual
Page 45 – Revision EU05-07-17
Flushing the Sanitizer from the Machine
10.
Place a pitcher, catch basin, or other container under the faucet of the
WL2FW Water Treatment
System.
Dispense at least 5 litres of ambient water and test with a test strip to ensure 0 parts per
million of sanitizer is left in the ambient circuit.
11.
Once ambient is clear, flush the cold tank. Run at least 10 Litres of water through the faucet by
dispensing cold water to dilute and remove the sanitizer from the cold circuit. You can use test
strips to evaluate the water and ensure 0 parts per million of sanitizer is left in the circuit.
12.
Once the sanitizer odour/taste has been flushed out of the cold and or ambient side of the
machine the sanitization process for the cold and or ambient circuits are now complete.
Fill the Hot Tank
13.
Press the Hot Water Select Button, followed by the main dispensing button to fill the hot tank.
Water will dispense from the faucet once the hot tank is full. Flush until water is clear.
WARNING!
HOT CIRCUIT IS NOT SANITIZED AND IS NOT REQUIRED.
Water in the hot circuit is not sanitary until the temperature exceeds 77°C (171
o
F) for at least
5 minutes.
UV System Functional Test
WARNING!
ULTRAVIOLET RADIATION.
Protect your skin and eyes against ultraviolet rays.
Never look directly at an operating UV light. Disconnect wiring before removing.
14.
Remove UV Firewall Lamp from Firewall housing. Remove Top Cover from Firewall housing.
Carefully remove Quartz Sleeve Spiral from Firewall Housing and inspect for cracks or other
damage. Reinsert Quartz Sleeve Spiral, replace Top Cover of Housing. Inspect UV lamp and
reinsert into Housing.
15.
Press dispensing button and check for blue glow from top of Firewall Housing and at Faucet
dispensing area to ensure UV lamp is operational.
Note
: UV Lamp Sensor is temperature sensitive. During extended periods of use, especially when
filling or draining the unit, when water is not being dispensed UV lamp sensor can overheat
initiating a UV fault. If this occurs turn off unit for 5 minutes and allow sensor to cool before
resuming operation
16.
Disconnect UV lamp to test UV lamp sensor operation. Unit should alarm and green indication
LED on front of unit should flash.
17.
Disconnect power to
WL2FW Water Treatment System.
18.
Reconnect UV lamp.
Summary of Contents for WL2FL Free Standing
Page 14: ...WL2 FW Manual Page 14 Revision EU05 07 17 HEATER CIRCUIT HOT TANK WIRING...
Page 37: ...WL2 FW Manual Page 36 Revision EU05 07 17 WL2FW FLOW DIAGRAM COLD ONLY...
Page 38: ...WL2 FW Manual Page 37 Revision EU05 07 17 COLD AND AMBIENT...
Page 39: ...WL2 FW Manual Page 38 Revision EU05 07 17 HOT AND COLD...
Page 41: ...WL2 FW Manual Page 40 Revision EU05 07 17...
Page 42: ...WL2 FW Manual Page 41 Revision EU05 07 17 120V 60Hz Power Source 120V 60Hz 120V 60Hz...
Page 43: ...Power Source 120V 60Hz 120V 60Hz 120V 60Hz WL2 FW Manual Page 42 Revision EU05 07 17...