FCB Operator’s Instructions
(Applies to V4 Units)
ÍÍÍÍ
ÍÍÍÍ
MS
(Forward)>
<(Backward)
Display
ON
MOTOR
Side 1
Side 2
BLEND
ON/OFF
SYRUP PRIME
OFF
ERROR
RESET
Manual Defrost
Menu/Select
Cancel Defrost
ER
*CONTROL PANEL SWITCH IDENTIFICATION
*THE CONTROL PANEL IS ACCESSIBLE BY
OPENING THE UNIT FRONT ACCESS DOOR
Syrup Out Side 1 or Syrup Out Side 2 Message (
see back for freeze cylinder location
)
If either freeze cylinder is out of syrup, a warning will “Beep” seven times. The message display will
indicate Syrup Out Side 1 or Syrup Out Side 2. This indicates the syrup supplying that freeze cylin-
der must be replaced.
Proceed as follows:
Bag-in-Box System
A.
Disconnect the syrup tube from the empty bag-in-box and remove the empty bag-in-box.
B.
Install a full bag-in-box and connect the syrup tube. Proceed to step C.
FCB Control Panel
C.
At the FCB panel, press and hold any one of the buttons for 5 seconds. This unlocks the panel
and allows programming.
D.
Press
Off 1
or
Off 2
depending on which cylinder is being replenished.
E.
Press and hold the SYRUP PRIME 1 or SYRUP PRIME
2
until the
Syrup Out Side 1
or
Syrup Out Side 2
message goes out.
F.
If the
Syrup OUT Side 1
or
Syrup OUT Side 2
message does not go out, repeat step E.
until it does.
G.
Slowly pull the relief valve ring on the faceplate to relieve the CO
2
pressure while the cylinder
is filling. When the cylinder is full, liquid will run from the tube.
H.
Press ON
1
or ON
2
to start the freeze process. The freeze cylinder beaters and the refrigera-
tion system will start automatically. Do not start unless the freeze cylinders are FULL.
See back for Bag-in-Box illustration and freeze cylinder location
Revision Date: May 09, 2014 Revision: B ©
1994-2014, Cornelius Inc. Publication Number: 3711
Revision Date: May 09, 2014 Revision: B
© 1998-2014, Cornelius Inc.
1 Publication Number: 560002989