WL2FL
Manual
Page 44 – Revision EU07-07-17
19.
Connect power to
WL2FL Water Treatment System.
Compressor Test
20.
Red Heater & Compressor to be in the on position
I=ON
. Always ensure tanks are
full of water before turning on the heater or the overheat (high limit) will open
and require manual reset. If the wire condenser at back of the unit is warm, the
refrigeration system is working.
I=ON
21. Once the
WL2FL Water Treatment System
reaches its target temperature, the compressor will
shut off. Draw a glass of cold water and verify it is has chilled to proper temperature.
Heater Test
22. Always ensure tanks are full of water before turning on the heater or the overheat (High Limit)
will open and require manual reset. It will take the heater approximately 10 minutes to heat the
water from ambient 24°C (75°F) to the factory set point of 87°C (187°F). Dispense a cup of hot
water to ensure the temperature/odour/taste is acceptable.
WARNING!
HOT WATER CAN BURN OR SCALD.
The
WL2FL Water Treatment System
produces Hot Water up to 87°C (187°F).
Water above 52°C (125°F) can cause severe burnsor
scalding. Hot water should be dispensed carefully into insulated container to avoid injury.
Summary of Contents for PUREZZA WL2FL FIREWALL
Page 1: ...WL2FL FIREWALL MANUAL...
Page 15: ...WL2FL Manual Page 15 Revision AU27 04 2023 HEATER CIRCUIT HOT TANK WIRING...
Page 21: ...WL2FL Manual Page 21 Revision AU27 04 2023 WL2FL MINI DRAWING AND PARTS LIST...
Page 26: ...WL2FL Manual Page 26 Revision AU27 04 2023 WL2FL FREE STANDING DRAWING AND PARTS LIST...
Page 32: ...WL2FL Manual Page 32 Revision AU27 04 2023 WL2FL FLOW DIAGRAM COLD ONLY...
Page 33: ...WL2FL Manual Page 33 Revision AU27 04 2023 COLD AND AMBIENT...
Page 34: ...WL2FL Manual Page 34 Revision AU27 04 2023 HOT AND COLD...
Page 36: ...WL2FL Manual Page 36 Revision AU27 04 2023...
Page 37: ...WL2FL Manual Page 37 Revision AU27 04 2023 120V 60Hz Power Source 120V 60Hz 120V 60Hz...
Page 38: ...Power Source 120V 60Hz 120V 60Hz 120V 60Hz WL2FL Manual Page 40 Revision EU07 07 17...