Closed Water Supply Valve
Open the Water Supply Valve
Cold Water Solenoid Valve
malfunction
Inspect the valve components for proper functionality.
Red Heater & Compressor
Switch on unit is off.
If water is dispensing at room temperature:
Turn Red Heater & Compressor Switch on.
I =ON
Loose connection(s) on the
Display PCB
Turn power off; unplug the
WL2FL Water Treatment System
and
visually inspect solenoid connections into the Display PCB. Verify
the soldering points on connections are secure into the board.
Remove the PCB to inspect the front of the board.
Exhausted Filter
Replace filters as needed.
Water Pressure is too high
Ensure input water pressure is between 2.5-3bar; Install pressure
reducer or regulator.
The correct input water pressure is critical to the performance of the
unit to allow solenoids to open.
Summary of Contents for PUREZZA WL2FL FIREWALL
Page 1: ...WL2FL FIREWALL MANUAL...
Page 15: ...WL2FL Manual Page 15 Revision AU27 04 2023 HEATER CIRCUIT HOT TANK WIRING...
Page 21: ...WL2FL Manual Page 21 Revision AU27 04 2023 WL2FL MINI DRAWING AND PARTS LIST...
Page 26: ...WL2FL Manual Page 26 Revision AU27 04 2023 WL2FL FREE STANDING DRAWING AND PARTS LIST...
Page 32: ...WL2FL Manual Page 32 Revision AU27 04 2023 WL2FL FLOW DIAGRAM COLD ONLY...
Page 33: ...WL2FL Manual Page 33 Revision AU27 04 2023 COLD AND AMBIENT...
Page 34: ...WL2FL Manual Page 34 Revision AU27 04 2023 HOT AND COLD...
Page 36: ...WL2FL Manual Page 36 Revision AU27 04 2023...
Page 37: ...WL2FL Manual Page 37 Revision AU27 04 2023 120V 60Hz Power Source 120V 60Hz 120V 60Hz...
Page 38: ...Power Source 120V 60Hz 120V 60Hz 120V 60Hz WL2FL Manual Page 40 Revision EU07 07 17...