WL2FL
Manual
Page 50 – Revision AUS-04-23
FAULT CODE TROUBLESHOOTING INDEX
1. Continuous Red Flashing Light and Continuous Audible Alarms
2. Green Flashing Light and 15 Second Audible Alarms
3. No LED Light
1. FAULT CODE:
Continuous Red Flashing Light and Continuous Audible Alarms
indicate that the Leak Detector has sensed water in the Leak Tray and will shut
down inlet solenoid.
Possible Reason
Solution
Water is present in the Bottom
Tray, causing the leak
detection to trigger.
*Leak Detection is on the Mini
Model only.
Remove the Top Cover and Front Panel. Tip the unit slightly
to drain, dry Bottom Tray completely.
Leak in
WL2FL Water
Treatment System
Mini
Water is in the bottom of the
WL2FL Water Treatment
System
. Clear Leak Detection Tray to ensure inside of unit is
dry.
Check for source of leak and fix as necessary.
Flashing Red Light
Summary of Contents for PUREZZA WL2FL FIREWALL
Page 1: ...WL2FL FIREWALL MANUAL...
Page 15: ...WL2FL Manual Page 15 Revision AU27 04 2023 HEATER CIRCUIT HOT TANK WIRING...
Page 21: ...WL2FL Manual Page 21 Revision AU27 04 2023 WL2FL MINI DRAWING AND PARTS LIST...
Page 26: ...WL2FL Manual Page 26 Revision AU27 04 2023 WL2FL FREE STANDING DRAWING AND PARTS LIST...
Page 32: ...WL2FL Manual Page 32 Revision AU27 04 2023 WL2FL FLOW DIAGRAM COLD ONLY...
Page 33: ...WL2FL Manual Page 33 Revision AU27 04 2023 COLD AND AMBIENT...
Page 34: ...WL2FL Manual Page 34 Revision AU27 04 2023 HOT AND COLD...
Page 36: ...WL2FL Manual Page 36 Revision AU27 04 2023...
Page 37: ...WL2FL Manual Page 37 Revision AU27 04 2023 120V 60Hz Power Source 120V 60Hz 120V 60Hz...
Page 38: ...Power Source 120V 60Hz 120V 60Hz 120V 60Hz WL2FL Manual Page 40 Revision EU07 07 17...