WL2FL FREE STANDING DRAINING INSTRUCTIONS
Draining Notes
Drain the
WL2FL Water Treatment System
for transportation.
WL2FL
Manual
Page 46 – Revision EU07-07-17
WARNING!
STORE UNIT EMPTY. ALWAYS SANITIZE BEFORE REUSE.
The unit must be completely drained and sealed before storing to avoid stagnation and reduce
microbial growth).
Prior to draining the Hot Tank, turn off the Red Heater and Compressor Power
Switch (
O=OFF)
, and dispense 2 Litres (½ Gallons) of hot water from the machine.
As hot water is dispensed from the faucet of the
WL2FL Water Treatment System
,
colder water will be introduced into the hot tank. Since the Red Heater and
Compressor Power Switch is turned off, the heater will not energize and heat the
incoming tap water. Following this precaution prevents exposing personnel and equipment
(drains, catch basin, etc.) to scalding hot water.
Disable Cold and Hot Tanks
8. Turn off the Red Heater and Compressor Power Switch (
O-OFF
) to disable the
heater and compressor.
9. Dispense 2 Litres (1 gallon) of water through the hot tank to cool thewater
temperature in the hot tank and avoid burns.
WARNING!
HOT WATER.
The
WL2FL Water Treatment System produces Hot Water up to
84°C (187°F).
Water above 52°C (125°F) can cause severe burns or scalding. Hot water should
be dispensed carefully into insulated container to avoid injury.
Turn off Water Supply and Bleed Water Pressure
10. Isolate the
WL2FL Water Treatment System
from incoming feed water by turning off the supply.
11. Dispense cold still water to relieve any pressure built up in the system.
12. Insert approx. 3 inches of blue tubing into the Line Bulkhead fitting at back of
the
WL2FL Water Treatment System
to allow water to drain.
13. Depress Cold Water Dispense Button until all Cold Water has drained from the
WL2FL Water Treatment System
.
14. Depress Hot Water Dispense Button until all Hot Water has drained from the
WL2FL Water Treatment System
.
Bulkhead Fitting
Summary of Contents for PUREZZA WL2FL FIREWALL
Page 1: ...WL2FL FIREWALL MANUAL...
Page 15: ...WL2FL Manual Page 15 Revision AU27 04 2023 HEATER CIRCUIT HOT TANK WIRING...
Page 21: ...WL2FL Manual Page 21 Revision AU27 04 2023 WL2FL MINI DRAWING AND PARTS LIST...
Page 26: ...WL2FL Manual Page 26 Revision AU27 04 2023 WL2FL FREE STANDING DRAWING AND PARTS LIST...
Page 32: ...WL2FL Manual Page 32 Revision AU27 04 2023 WL2FL FLOW DIAGRAM COLD ONLY...
Page 33: ...WL2FL Manual Page 33 Revision AU27 04 2023 COLD AND AMBIENT...
Page 34: ...WL2FL Manual Page 34 Revision AU27 04 2023 HOT AND COLD...
Page 36: ...WL2FL Manual Page 36 Revision AU27 04 2023...
Page 37: ...WL2FL Manual Page 37 Revision AU27 04 2023 120V 60Hz Power Source 120V 60Hz 120V 60Hz...
Page 38: ...Power Source 120V 60Hz 120V 60Hz 120V 60Hz WL2FL Manual Page 40 Revision EU07 07 17...