RESETTING THE HOT TANK OVERHEAT OR HIGH LIMIT SAFETY
1.
Red Compressor/Heater Switch must be in the
O=OFF
position
2.
Unplug the Power Cord from rear of
WL2FL Water Treatment System.
3.
Free Standing Model: Remove the Lower Front Panel by removing the Phillips Head
Screws underneath the Lower Front Panel.
Mini Model: Remove the Side Panel by removing Phillips Head Screws from Side Panel.
4.
Locate the Protective Metal Box on the rear of the hot
tank. As you look through the condenser coils on the
rear of the unit, you will see the hot tank located on the
right-hand side.
5.
From the front of the Water Treatment System, reach
up behind the hot tank and take hold of the protective
metal box covering the thermostat and overheat on the
hot tank.
There are nuts that secure the Protective Metal Box to
the Hot Tank, are loose enough to allow you to remove
the Protective Metal Box.
If the nuts on the metal box are too tight, loosen the
nuts securing the Hot Tank to the upper base of the
WL2FL Water Treatment System
unit and lower the
Hot Tank so you can remove the Protective Metal Box.
Summary of Contents for PUREZZA WL2FL FIREWALL
Page 1: ...WL2FL FIREWALL MANUAL...
Page 15: ...WL2FL Manual Page 15 Revision AU27 04 2023 HEATER CIRCUIT HOT TANK WIRING...
Page 21: ...WL2FL Manual Page 21 Revision AU27 04 2023 WL2FL MINI DRAWING AND PARTS LIST...
Page 26: ...WL2FL Manual Page 26 Revision AU27 04 2023 WL2FL FREE STANDING DRAWING AND PARTS LIST...
Page 32: ...WL2FL Manual Page 32 Revision AU27 04 2023 WL2FL FLOW DIAGRAM COLD ONLY...
Page 33: ...WL2FL Manual Page 33 Revision AU27 04 2023 COLD AND AMBIENT...
Page 34: ...WL2FL Manual Page 34 Revision AU27 04 2023 HOT AND COLD...
Page 36: ...WL2FL Manual Page 36 Revision AU27 04 2023...
Page 37: ...WL2FL Manual Page 37 Revision AU27 04 2023 120V 60Hz Power Source 120V 60Hz 120V 60Hz...
Page 38: ...Power Source 120V 60Hz 120V 60Hz 120V 60Hz WL2FL Manual Page 40 Revision EU07 07 17...