Mk5 Milk Meter           Compteur a Lait Mark V 
Technical Manual        Manuel Technique 

 
OPERATION    UTILISATION

 

16

 

10 February 1995

 

 

5. 

OPERATION 

 

5.1.  TO OPERATE THE METER WITH OPEN 
BOTTOM  FLASK 
 
1. 

Wet flask tap centre before use. 

 
 
2. 

Close  flask  tap  by  turning  to  horizontal 

position. Rock tap in its seat to ensure the tap 
is firmly seated. 
 
 
3. 

Place cups on cow.  Milk in usual manner. 

 
4. 

Remove  cups  from  cow.    Milk  Meter 

should still be under vacuum. 
 
 
5. 

Read  Milk  Level  (ignoring  froth)  in  the 

measuring  flask  to  give  milk  yield  in  kg  or  lb. 
(allow  time  for  excessive  froth  to  settle  before 
reading). 
 
 
6. 

If a milk sample is required for testing,  

     
     a.  Turn  flask  tap  down  to  the  sampling    
 

position. 

     
     b. Allow  air  to  be  admitted  into  the 
 

measuring flask for one second per kg of 

 

milk,  a  minimum  of  ten  seconds.  eg  for 

 

25  kg's  of  milk  allow  air  to  be  admitted 

 

for a minimum of 25 seconds. 

     c. Operate the flask depressor to draw off a 
 

sub sample of milk as required. 

 
 
 
 
7. 

To  empty  flask  turn  tap  up  and  operate 

flask depressor.  Wait a few seconds after flask 
drains  and  operate  flask  depressor  again  if 
necessary. 
 
 
 
8. 

Turn flask tap to horizontal for next cow or 

leave pointing up for washing. 
 

 

5. UTILISATION 
 
 
5.1.  UTILISATION  DU  COMPTEUR  AVEC 
RESERVE A FOND OUVERT 
 
1.  Humidifier  le  logement  du  robinet  de  la 
réserve avant utilisation 
 
2.  Fermer  le  robinet  de  la  réserve  en  le 
tournant  jusque  sa  position  horizontale  (voir 
Fig 5.1a).      Bien enfoncer le robinet dans son 
logement afin d’assurer sa position. 
 
3.  Placer  les  manchons  trayeurs  sur  le  pis  de 
la vache et traire de manière habituelle. 
 
4.  Retirer  les  manchons  trayeurs.  A  ce 
moment,  le  compteur  à  lait  doit  toujours  être 
sous pression de vide. 
 
5. Lire le niveau du lait (sans tenir compte de la 
mousse) sur la réserve graduée pour obtenir la 
quantité  de  lait  produite  en  kg  ou  livres 
(éventuellement  laisser  la  mousse  reposer 
avant d’effectuer la lecture). 
 
6.  Si  un  échantillon  de  lait  est  demandé  pour 
un test ultérieur : 
     a.  Tourner  le  robinet  de  la  réserve  vers  le 
 

bas en position prise d’échantillon 

 

(voir Fig 5.1b). 

      b.Laisser  écouler  le  contenu  total  de  la 
 

réserve  comme  échantillon  (en  appuyant 

 

sur  l’onglet de mise hors pression  situé   

 

en haut de la réserve) dans un  récipient. 

     
      c.Mélanger  l’échantillon  en  le  transvasant 
 

au  moins  trois  fois  d’un  récipient  à 

 

l’autre. 

      d. Recueillir un sous échantillon à partir du 
 

lait mélangé. 

 
7.  Pour  vider  la  réserve,  tourner  le  robinet  en 
position verticale (voir Fig 5.1c) et appuyer sur 
l’onglet  de  mise  hors  pression.  Attendre 
quelques  secondes  après  l’écoulement  du  lait 
de la réserve et actionner l’onglet de mise hors 
pression à nouveau si nécessaire. 
 
8.  Tourner  le  robinet  de  la  réserve  en  position 
horizontale  pour  la  prochaine  vache  ou  le 
laisser  en  position  verticale  pour  la  phase  de 
lavage. 
 

Summary of Contents for MK5

Page 1: ...MARK 5 MILK METER TECHNICAL MANUAL COMPTEUR A LAIT MARK V MANUEL TECHNIQUE C 1993 1995 InterAg Hamilton New Zealand...

Page 2: ...OCEDURE 18 6 1 1 BEFORE MILKING 18 6 1 2 IMMEDIATELY AFTER USE 19 6 1 3 REVERSE FLOW CLEANING SYSTEMS 19 6 1 4 ALKALINE DETERGENTS 19 6 2 MANUAL CLEANING PROCEDURE 20 7 ROUTINE MAINTENANCE 21 8 MILKIN...

Page 3: ...NT LA TRAITE 18 6 1 2 IMMEDIATEMENT APRES UTILISATION 19 6 1 3 SYSTEMES DE NETTOYAGE PAR FLUX INVERSE 19 6 1 4 DETERGENTS ALCALINS 19 6 2 METHODE DE NETTOYAGE MANUEL 20 7 MAINTENANCE DE ROUTINE 21 8 C...

Page 4: ...ents 1 INTRODUCTION Le compteur lait Waikato est un dispositif de mesure proportionnel de la quantit de lait produite situ entre le tuyau lait de chaque poste et la ligne de lait Le compteur lait s pa...

Page 5: ...cision selon les crit res de ICAR International Commitee for Animal Recording et du DHIA Homologu ind pendamment pour utilisation dans quinze des plus grands pays laitiers du monde Possibilit s de me...

Page 6: ...ait D par lequel monte le lait venant de la griffe avec chaque pulsation de la machine traire Des ailettes en spirale C situ es dans la partie haute du tube d admission impriment une rotation au lait...

Page 7: ...place 3 2 CAPACITES DE LA RESERVE GRADUEE a R serve pour 30kg Homologu e ICAR moul e en une seule pi ce b R serve pour 42kg Couvercle de r serve et joint amovibles pour nettoyage lorsque n cessaire L...

Page 8: ...Fig 3 2c for flat surfaces or piping Wedge Mounting Set Fig 3 2 d and e for flat surfaces or piping Hanger bracket Fig 3 2 f off piping 3 4 POSSIBILITES DE MONTAGE Le compteur lait peut tre mont de m...

Page 9: ...che suspendue Wedge mounting kit V Packer U Bolt kit Wedge mounting bracket Spine Wedge block Stem Wedge block kit Hanger bracket 38050141 38050265 38050186 38050263 38050182 37112000 38050706 Fig 3 2...

Page 10: ...ermany Holland Sweden Ireland New Zealand Korea Scotland Wales South Africa Denmark United States of America 3 5 DIFFERENCES DE MARQUES Le compteur lait Waikato Mk5 est distribu dans la plupart des pa...

Page 11: ...5 38050505 38050505 R Stainless Steel Connector 38050704 38050704 38050704 IR S S Connector Assembly 38050166 38050166 38050166 K Hose 38050506 38050506 38050506 L 2 Flask 30kg 38050164 L 3 Flask 42kg...

Page 12: ...0505 38050505 38050505 R Raccord inox 38050704 38050704 38050704 IR Raccord inox complet 38050166 38050166 38050166 K Tuyau 38050506 38050506 38050506 L 2 R serve 30kg 38050164 L 3 R serve 42kg 380501...

Page 13: ...ovac and the Duovac switched to manual 4 1 EMPLACEMENT voir Fig 4 1 Le compteur lait est install partir du tuyau lait entre le faisceau de traite et la tuyauterie de la ligne de lait Il doit tre insta...

Page 14: ...chnique INSTALLATION 14 10 February 1995 High Line Mid Line Curb Low Line Cow Floor ACR Vacuum Tap Fig 4 1 Installation of Milk Meters Ligne Haute Ligne Centrale Decrochage Automatique Ligne Basse Bor...

Page 15: ...odified ball cage assembly fitted 4 5 CONVERSION DU COMPTEUR WAIKATO DE 30kg 65lb 42kg 92lb A l exception de la r serve des bouchons de r serve type ouvert ou ferm et de la chambre de la bille inox to...

Page 16: ...e la r serve avant utilisation 2 Fermer le robinet de la r serve en le tournant jusque sa position horizontale voir Fig 5 1a Bien enfoncer le robinet dans son logement afin d assurer sa position 3 Pla...

Page 17: ...r releases sample via tap outlet POSITION PRISE D ECHANTILLON Sortie du robinet orient e vers le bas pour l admission d air dans la r serve pour agiter le lait En appuyant sur l onglet de mise hors pr...

Page 18: ...as per the cleaning procedure section of this manual 5 2 UTILISATION DU COMPTEUR AVEC RESERVE A FOND FERME Pour une lecture de la r serve gradu e et une prise d chantillon pour analyse ult rieur hors...

Page 19: ...eter has not been used for several days 6 METHODES DE NETTOYAGE Dans la pratique le compteur lait Waikato Mk5 peut tre nettoy de mani re satisfaisante avec un dispositif de nettoyage en place n anmoin...

Page 20: ...fect of this 6 1 2 IMMEDIATEMENT APRES UTILISATION 1 Rincer l installation de traite avec les compteurs lait en place en utilisant de l eau soit froide soit ti de jusqu ce que l eau vacu e sorte incol...

Page 21: ...shake to clean A sponge may be used to remove stubborn deposits 3 Rinse with ample fresh warm water 6 2 METHODE DE NETTOYAGE MANUEL A utiliser comme partie int grante de la M thode de R vision P riodi...

Page 22: ...ction and Periodic Test at least once annually 7 MAINTENANCE DE ROUTINE De par sa conception le compteur lait ne requiert qu un minimum de maintenance Toutefois et comme faisant partie de ses connaiss...

Page 23: ...eters are fitted Note On no account should the vacuum level ever be set greater than 50kPa 15 Hg 8 CONDITIONS REQUISES PAR LA MACHINE A TRAIRE Pour assurer un bon tat physique et sanitaire des vaches...

Page 24: ...exit hole in the cup Any abnormal restrictions such as these can affect Milk Meter accuracy 8 3 ENTREE D AIR AU NIVEAU DE LA GRIFFE L admission d air au niveau de la griffe est essentiel afin d assur...

Page 25: ...ycerine on the mating surfaces would help here 9 PROBLEMES DE FONCTIONNEMENT 9 1 INCIDENTS 9 1 1 BULLES D AIR DANS LE LAIT DE LA RESERVE Cause robinet trois voies us sec ou mal plac Rem de remplacer h...

Page 26: ...tterfat samples not taken in duplicate 9 2 PROBLEMES DE PRECISION 9 2 1 VERIFICATION DE LA PRECISION DES COMPTEURS PAR DEUX METHODES a Comparer la production individuelle d une vache en pesant s par m...

Page 27: ...ease cleaning solution volume Flow rate Concentration Temperature A cleaning system that is clearly inadequate would require redesigning for efficient cleaning 9 3 PROBLEMES DE NETTOYAGE Si le syst me...

Page 28: ...solvents to clean Milk Meter parts 10 REVISION PERIODIQUE Au moins une fois par an tous les compteurs lait doivent tre contr l s selon la m thode suivante voir Fig 3 3 pour le rep rage des pi ces 10...

Page 29: ...and Recalibration Contr ler soigneusement les pi ces suivantes du compteur selon leur degr d usure tat des surfaces coupures fentes et rayures Robinet trois voies Tuyaux d entr e et de sortie Bouchon...

Page 30: ...source hose B 5 Volumetric flasks or accurate scales will be required 11 METHODE DE TEST PERIODIQUE Conjointement avec la r vision p riodique tous les compteurs doivent tre test s pour leur pr cision...

Page 31: ...er and repeat the procedure to obtain two results per Meter 11 2 METHODE POUR TEST DE BASE 1 Remplir le seau D avec 16 litres d eau 16kg ou 35 24lb qui sera le fluide de travail 2 Ouvrir le robinet d...

Page 32: ...se Tap C Supply Pail E fitted to lowest point Flow Restrictor R duction de d bit Flow Control Tube Tube de contr le F Air Admission 600mm from Milk Meter inlet Fig 11 1 Basic Milk Meter Test Rig To Va...

Page 33: ...tted to a certified service agent for repair and recalibration Note The periodic test procedure should be regularly followed to give confidence in Milk Meter results 11 3 ANALYSE DES RESULTATS Calcule...

Page 34: ...for any points of non compliance with these recommended procedures 12 REPARATIONS ET METHODE D ETALONNAGE Ce paragraphe traite de la r paration et de l talonnage du compteur lait Waikato qui ne peut t...