WAGO-I/O-SYSTEM 750 XTR
Table of Contents
5
750-8212/040-010 PFC200 G2 2ETH M12 RS XTR
Manual
Version 1.0.0, valid from FW version 03.01.07(13)
Inserting the Controller ...................................................................... 92
Inserting the I/O Module .................................................................... 93
Power Contacts/Field Supply ................................................................. 95
Connecting a Conductor to the CAGE CLAMP
.................................... 96
Power Supply Concept .......................................................................... 97
Supplementary Power Supply Regulations ....................................... 98
Supply Example .............................................................................. 100
Power Supply Units ......................................................................... 102
Grounding the DIN Rail ................................................................... 103
Framework Assembly ................................................................. 103
Insulated Assembly .................................................................... 103
Grounding Function ......................................................................... 104
Fieldbus Cables............................................................................... 105
Shielded Signal Lines ...................................................................... 106
WAGO Shield Connecting System .................................................. 106
Switching On the Controller ................................................................. 107
Determining the IP Address of the Host PC ......................................... 108
Setting an IP Address .......................................................................... 109
Assigning an IP Address using DHCP ............................................ 110
Changing an IP Address Using the “CBM” Configuration Tool
and a Terminal Program.................................................................. 111
Changing an IP Address using “WAGO Ethernet Settings” ............ 114
Temporarily Setting a Fixed IP Address .......................................... 116
Testing the Network Connection .......................................................... 117
Changing Passwords ........................................................................... 118
Initiating Reset Functions ..................................................................... 120
Warm Start Reset ............................................................................ 120
CODESYS 2 Runtime System .................................................... 120
Runtime System ..................................................... 120
Cold Start Reset .............................................................................. 120
CODESYS 2 Runtime System .................................................... 120
Runtime System ..................................................... 120
Software Reset ................................................................................ 121
Configuration via Web-Based-Management (WBM) ....................... 123
WBM User Administration .......................................................... 124
General Information about the Page .......................................... 127
“Status Information” Page ........................................................... 129
“Controller Details” Group ...................................................... 129
“Network Details Xn” Group(s) ............................................... 129
“PLC Runtime Information” Page ............................................... 131
“PLC Runtime” Group ............................................................ 131