36
EDITION 08/2022
ORDER NUMBER DOC2368104
Peristaltic pump
6.4.2 RECOMMENDED SETTINGS FOR COMPRESSED AIR
Input air pressure:
0.6-0.8 MPa; 6-8 bar; 87-116 psi
Air consumption:
5-7 Nm3/h
P_03086
Peristaltic pump
type
Pressure
of feed/
vortex air
[bar]
Pressure of
control air
[bar]
Vortex air
throttle 1
Vortex air
throttle 2
Feed air
throttle 1
Cycle times [sec.]
PP25S
3.5
4.0
3-4
6-7
2.5/0.3/2.5/0.3
PP25C
3.5
4.0
3-4
6-7
2.5/0.3/2.5/0.3
PP40S
3.5
4.0
4-5
7-9
2.5/0.3/2.5/0.3
PP40C
3.5
4.0
4-5
7-9
2.5/0.3/2.5/0.3
PP25Y/PP25Y-FL
3.5
4.0
3-4
3-4
6-7
1.5/0.3/1.5/0.3
PP40Y
4.5
4.0
3-4
3-4
8-10
1.5/0.3/1.5/0.3
5-cycle operation
Peristaltic pump
type
Pressure
of feed/
vortex air
[bar]
Pressure of
control air
[bar]
Vortex air
throttle 1
Vortex air
throttle 2
Feed air
throttle 1
Cycle times [sec.]
PP25S
3.5
4.0
3-4
6-7
2.0/0.3/1.4/0.6/0.6
PP25C
3.5
4.0
3-4
6-7
2.0/0.3/1.4/0.6/0.6
PP40S
3.5
4.0
4-5
7-9
2.0/0.3/1.4/0.6/0.6
PP40C
3.5
4.0
4-5
7-9
2.0/0.3/1.4/0.6/0.6
PP25Y/PP25Y-FL
3.5
4.0
3-4
3-4
6-7
2.0/0.3/1.4/0.6/0.6
PP40Y
4.5
4.0
3-4
3-4
8-10
2.0/0.3/1.4/0.6/0.6
6.5
CONNECTION DIAGRAM
The connection diagrams of the WAGNER controls, for the peristaltic pump, are included in the supplied
electrical circuit diagram.