![VTS Medical Systems VTS5000 Series Operating Instructions Manual Download Page 81](http://html1.mh-extra.com/html/vts-medical-systems/vts5000-series/vts5000-series_operating-instructions-manual_1056181081.webp)
77
FC.08
Cooling fan control
0: auto control mode
1: always running when power on
1
0
o
FC.09
Password of
operation limiting
function
0~65535
Note 1: the password will take into effect
3 minutes later after set successfully
Note 2: this parameter cannot be
initialized.
1
0
o
FC.10
Operation limiting
function
0: disabled
1: enabled
Note: this parameter cannot be initialized
1
0
o
FC.11
Limiting time
0~65535(h)
Note: this parameter cannot be initialized
1
0
×
FC.12
Freq. decreasing
point of
instantaneous power
failure
220V: 180~330V 250V
380V: 300~550V 450V
1V
Depending
on model
×
FC.13
Freq. decreasing
factor of
instantaneous power
failure
0: the function of immunity to transient
power failure is disabled
1~100
1
0
o
FC.14
Droop control
0.00~10.00Hz
0.00: droop control function is disabled
Note : When F0.18=1(high frequency
mode) , upper limited is 100.0Hz
0.01Hz
0.00
×
FC.15
Delay time of
rotating speed
tracking
0.1~5.0S
0.1S
1.0
×
FC.16
Current amplitude
80%~200%*VFD rated current
1%
100%
×