![VTS Medical Systems VTS5000 Series Operating Instructions Manual Download Page 69](http://html1.mh-extra.com/html/vts-medical-systems/vts5000-series/vts5000-series_operating-instructions-manual_1056181069.webp)
65
F8.06
Integral time Ti1
0.01~10.00s
0.01s
0.05
o
F8.07
Derivative time
Td1
0.01~10.00s
0.0: no derivation
0.01s
0.00
o
F8.08
Sampling cycle T
0.01~10.00s
0.00: auto
0.01s
0.10
o
F8.09
Error limit
0.0~100.0%
0.1%
0.0%
o
F8.10
Close-loop preset
freq.
0.00~upper limit freq.
0.01Hz
0.00
o
F8.11
Preset freq. hold
time
0.0~3600.0s
0.1s
0.0
×
F8.12
Sleep mode
0: disabled
1: sleep when feedback pressure
exceeding or lower than sleep threshold
2: sleep when feedback pressure and
output frequency are stable
1
1
×
F8.13
Stop method of
sleep mode
0: decelerate to stop
1: coast to stop
1.00
0
o
F8.14
Deviation limit of
feedback when
entering sleep
state compared
with set pressure
0.0~20.0%
Note: this parameter is only valid to the
second sleep mode.
0.1%
0.5%
o
F8.15
Threshold value of
sleeping
0.0~200.0%
Note: this threshold value is the
percentage of given pressure, and it is
only valid for the first sleep mode.
0.1%
100.0%
o
F8.16
Threshold value of
awaking
0.0~200.0%
Note: this threshold value is the
0.1%
90.0%
o