175
0100H write data of F1.00
0002H item count of write menu, i.e. two items of F1.00 and F1.01
4034H 16 bits of CRC check code
Example:
Name
Frame format
Set F1.00, F1.01 at 1 and 0.02
respectively
Send frame: 01H 10H 0100H 0002H 04H 0001H 0002H 2E3EH
Return frame: 01H 10H 0100H 0002H 4034H
Forward and communicate
reference frequency at 50HZ
Send frame: 01H 10H 2000H 0002H 04H 0001H 1388H 36F8H
Return frame: 01H 10H 2000H 0002H 4A08H
Set F1.00 at 1
Send frame: 01H 10H 0100H 0001H 02H 0001H 7750H
Return frame: 01H 10H 0100H 0001H 0035H
6) 13H read single parameter(including attribute, min.value, max.value)
Inquiry information frame format(send frame):
Address
01H
Function
13H
Starting data address
00H
0CH
Number of Data(Byte)
00H
04H
CRC CHK High
45H
CRC CHK Low
CBH
Analysis of this segment data:
01H address of the driver
13H read function code
000CH start address, equivalent to F0.12 of control panel
0004H register amount
Summary of Contents for VTS5000 Series
Page 201: ...Version V0119A...