117
-200.0%~200.0%
note: range is relevant to F6.00
100.0%
AI1
、
AI2 multi curve choose through F6.36, as
figure F6-2.
Figure F6-2 AImulti point curve diagram
F7 digital input and output
F7.00
Input terminal X1 function (when F8.21 is
non-zero, default as function NO.58)
0~99
1
F7.01
Input terminal X2 function (when F8.21 is
non-zero, default as function NO.59)
0~99
2
F7.02
Input terminal X3 function (when F8.21 is
non-zero, default as function NO.60)
0~99
4
F7.03
Input terminal X4 function (when F8.21 is
non-zero, default as function NO.61)
0~99
7
F7.04
Input terminal X5 function (when F8.21 is
non-zero, default as function NO.62)
0~99
8
F7.05
Input terminal X6 function (when F8.21 is
non-zero, default as function NO.63)
0~99
0
F7.06
Input terminal X7 function
0~99
45
F7.07
reserved
—
0
0: control terminal idle
1: forward running(FWD)
Short-circuit terminal with COM, VFD runs
forward. Valid only when F0.06=1.
2: reverse running(REV)
Short-circuit terminal with COM, VFD runs
reverse. Valid only when F0.06=1.
3: three-wire running control
Refer to function description of running mode 2,
3 (three-wire control mode 1, 2) of F7.11.
4: forward jog control