41
F 1.07
Time ratio of ending
segment in S curve
10.0~50.0%
0.1%
20.0%
o
F 1.08
Stop mode
0: Decelerate to stop
1: coast to stop
1
0
×
F 1.09
Frequency threshold
of DC brake
0.00~
【
F0.16
】
upper limit frequency
0.01Hz
0.00
o
F 1.10
DC brake delay time
0.0~100.0s
0.1s
0.0
o
F 1.11
DC brake current
0.0~150.0%*rated current of motor
0.1%
0.0%
o
F 1.12
DC brake time at stop
0.0~100.0s
0.1s
0.0
o
F 1.13
Acc time 2
0.1 ~ 3600.0s
0.4 ~ 4.0KW 7.5s
5.5 ~ 30.0KW 15.0s
37.0 ~ 132.0KW 40.0s
160.0~ 630.0KW 60.0s
0.1
Depending
on model
o
F 1.14
Dec time 2
0.1
Depending
on model
o
F 1.15
Acc tinme 3
0.1
Depending
on model
o
F 1.16
Dec time 3
0.1
Depending
on model
o
F 1.17
Acc timne 4
0.1
Depending
on model
o
F 1.18
Dec time 4
0.1
Depending
on model
o
F 1.19
Acc/Dec time unit
0: second 1: minute 2: 0.1s
1
0
o
F 1.20
Frequency setting of
forward jog
operation
0.00~
【
F0.16
】
upper limit frequency
0.01Hz
5.00
o
F 1.21
Frequency setting of
reverse jog operation
0.00~
【
F0.16
】
upper limit frequency
0.01Hz
5.00
o