![VTS Medical Systems VTS5000 Series Operating Instructions Manual Download Page 40](http://html1.mh-extra.com/html/vts-medical-systems/vts5000-series/vts5000-series_operating-instructions-manual_1056181040.webp)
36
F0.00
User password
0~65535
Note 1: 0~9;without password protect
Note 2: it takes 3 minutes to take effect
of the successfully set password
Note 3: invalid for write-protect, and
can not be initialized.
1
0
o
F 0.01
Control
software
version
1.00~99.99
0.01
1.00
◆
F 0.02
Operation
panel
software version
1.00~99.99
0.01
1.00
◆
F 0.03
VFD rated power
0.4~999.9KW(G/P)
0.1KW
Depending
on model
◆
F 0.04
VFD type
0: G type(constant torque load type)
1: P type(fan, water pump load type)
Note 1: set as P type, and the VFD
parameters will refresh automatically,
without modifying any parameter the
VFD can be used as inverter of higher
grade for application of fan and water
pump.
Note 2: can not be initialized, please
modify it manually.
1
0
×
F 0.05
Control mode
0: common V/F control (manually torque
boost)
1: advanced V/F control (automatically
torque boost)
2: open loop current vector control (SVC)
3: closed loop currnt vector control
1
Depending
on model
×
Summary of Contents for VTS5000 Series
Page 201: ...Version V0119A...