43
F 1.36
Standby deceleration
time when
emergency brake
0.1~3600.0s
0.1s
1.0
o
F1.37
Current continuous
time when DC
braking
0.0~100.0s
0.1s
0.0
o
P2 Group - Motor Parameters
F 2.00
Motor type
0: AC asynchronous motor
1: PMSM(reserved)
Note 1: only closed-loop vector control is
acceptable by synchronous machine at
present
Note 2: this parameter can not be
initialized, please modify it manually.
1
0
×
F 2.01
Motor’s rated power
0.4~999.9KW
0.1KW
Depending
on model
×
F 2.02
Motor’s rated freq.
0.01Hz~
【
F0.15
】
maximum freq.
0.01Hz
50.00
×
F 2.03
Motor’s rated speed
0~60000RPM
1RPM
Depending
on model
×
F 2.04
Motor’s rated voltage
0~999V
1V
Depending
on model
×
F 2.05
Motor’s rated current
0.1~6553.5A
0.1A
Depending
on model
×
F 2.06
Stator resistance of
asynchronous motor
0.001~20.000Ω
0.001Ω
Depending
on model
×
F 2.07
Rotor resistance of
asynchronous motor
0.001~20.000Ω
0.001Ω
Depending
on model
×
Summary of Contents for VTS5000 Series
Page 201: ...Version V0119A...