![VP ShiniCube 1600TL User Manual Download Page 49](http://html1.mh-extra.com/html/vp/shinicube-1600tl/shinicube-1600tl_user-manual_1052319049.webp)
Displayed
code
Fault description
Recommended solution
E001
Relay fault
Tab. 6-2: Fault code and solution
E002
The voltage at the
grid side is too high
E003
Abnormity of CPU
synchronous communication
E004
E ROM read-write
abnormity
2
E006
Leakage current
detecting circuit fault
E009
The AC voltage
output is too high
E010
The DC voltage branched
from the AC voltage output
is too high
E011
The BUS voltage
is too high
E012
The BUS voltage is
too low
E013
The IGBT temperature
is too high
E014
BOOST fault
E015
E017
E022
E023
E024
Inverting fault
The BUS capacity is aged
1.Cut off the DC breaker;
2.Wait for several seconds till the LCD
panel turns off, and then close the DC
breaker and restart the inverter;
3.If the above operation is made but the
inverter can still not work normally,
please ask for professional service.
1.These faults arise from normal aging of
device elements or damage of consuma-
bles, and the inverter can still generate
power normally;
2 If such faults are found, please replace
the corresponding element, and contact
the professional service man.
.
The voltage dependent
resistor at the output side
is broken
The voltage dependent
resistor at the input side
is broken
FLASH read-write
abnormity
Troubleshooting and maintenance
ShiniCube1600TL-3300TL User Manual
Victory Power New Energy
VP-UMSC1.0.0EN
40