Fig. 3-12 Schematic drawing for the electrical cable connection of the inverter
PV Array
SPD
Inverter
RCD
SPD
GRID
DC
Breaker
AC
Breaker
The PV array is connected to the inverter via a DC breaker, the inverter is connected to the
grid via an AC breaker and a residual current device (RCD), and surge protection device
(SPD) are configured on the AC and DC sides respectively.
ShiniCube supports two flexible communication modes: RS485 and optional wireless
Zigbee. The topological structure of the communication connection is introduced below.
1) Single device communication mode 1 (RS485)
Communication between a single device and a PC
See the figure below for the connecting method, a pair of A/B terminals on the inverter is
connected to the A/B terminals on the RS485/RS232 or RS485/USB switch, and the other
end of the switch is connected to the computer.
Fig. 3-13: Schematic drawing for the single device communication mode 1
3.6.1 Electric and electrical system structure
The electric and electrical connection for the whole solar energy power generation system
is shown as below:
No load can be directly connected to the output side of the inverter.
3.6.2 Structure of the communication system
Tip
See 3.6.3 for the detailed wiring terminals and 3.6.4 for the
detailed wiring steps.
RS232/USB
R 485
S
Installation
ShiniCube1600TL-3300TL User Manual
Victory Power New Energy
VP-UMSC1.0.0EN
16