When the inverter enters the protection or fault state, and there are two or more
protection or fault codes at the same time, in this case it means the system or inverter
may be involved with two or more faults. The code below the protection or fault symbol
will change alternatively in different protection or fault states.
Fig. 5-7: LCD panel displaying two faults alternatively at the same time
5.4.5 Sleeping state
If the DC voltage output from the solar battery at the DC side is lower than 100V (minimum
initiating voltage) and there is voltage at the grid side, the inverter will enter the sleeping
mode and the LCD panel will display nothing. In this case the related data can be reviewed
if knocking the inverter shell by a finger slightly.
Fig. 5-8: Reviewable LCD panel at the sleeping state
If the DC voltage output from the solar battery at the DC side is lower than 100V (minimum
initiating voltage) and there is no voltage at the grid side, the inverter will enter the
power-off mode and the LCD panel will display nothing.
5.4.6 Power-off state
Human-machine interaction
ShiniCube1600TL-3300TL User Manual
Victory Power New Energy
VP-UMSC1.0.0EN