![VP ShiniCube 1600TL User Manual Download Page 43](http://html1.mh-extra.com/html/vp/shinicube-1600tl/shinicube-1600tl_user-manual_1052319043.webp)
See the following content for the meaning of each state.
5.4.1 Standing-by state
When the DC voltage output from the solar battery at the DC side is higher than 100V
(min. initiating voltage) but lower than 150V (min working voltage), the inverter will enter
the standing-by state and not supply power to the gird. In this case, the inverter will keep
monitoring the voltage on the solar batter board, and will enter the power generating
state once it reaches the working voltage 150V.
Fig. 5-3: LCD panel at the standing-by state
5.4.2 Power generating state
The inverter will enter the power generating state if the DC voltage output from the solar
battery board at the DC side is higher than 150V.
Fig. 5-4: LCD panel at the power
generating state
Human-machine interaction
ShiniCube1600TL-3300TL User Manual
Victory Power New Energy
VP-UMSC1.0.0EN
34
/47