![Vonsch Quatrofrem Series Configuration And Diagnostics Download Page 88](http://html1.mh-extra.com/html/vonsch/quatrofrem-series/quatrofrem-series_configuration-and-diagnostics_1049784088.webp)
UNIFREM v.3.41x
10 May 2017
Page 88 from 180
Name [ID]
Description
Def.
LB1_1 switch-on
[578]
Conditions for switching on the LB1_1.
-
-
÷
-
LB1_1
switch-
off [579]
LB1_1 switch-off: In case of a numeric signal if the signal value is lower than the
defined level.
-
-
÷
-
LB1_2
Signal
[580]
Signal selection for the 2nd input of LB1. It will be processed according to the
selected operation. Either numeric or discrete signal can be chosen.
-
Signal
LB1_2 switch-on
[581]
Conditions for switching on the LB2.
-
-
÷
-
LB1_2
switch-
off [582]
LB1_2 switch-off: In case of a numeric signal if the signal value is lower than the
defined level.
-
-
÷
-
LB2 (Fast)
Group of parameters number [168]
Second quick logical operation setting (1ms reaction time).
MENU \ SETTINGS \ FUNCTIONS \ PLC FUNCTIONS \ LOGICAL BLOCKS \ LB2 (FAST)
Name [ID]
Description
Def.
LB2 Operation
[626]
Logical operation type that will be used for the logical block. Configuration possibilities
are the same as in LB 1 LB1 Operation [625] (page 87).
OR
Look choises of parameter's LB1 Operation [625] (page 87)
LB2 Level [1009]
Input and output type of the logical block. Configuration possibilities are the same as
in LB 1 LB1 Level [1008] (page 87).
Look choises of parameter's LB1 Level [1008] (page 87)
LB2_1
Signal
[583]
Signal selection for the 1st input of LB2. It will be processed according to the selected
operation. Either numeric or discrete signal can be chosen.
-
Signal
LB2_1 switch-on
[584]
Conditions for switching on the LB2_1.
-
-
÷
-
LB2_1
switch-
off [585]
LB2_1 switch-off: In case of a numeric signal if the signal value is lower than the
defined level.
-
-
÷
-
LB2_2
Signal
[586]
Signal selection for the 2nd input of LB2. It will be processed according to the
selected operation. Either numeric or discrete signal can be chosen.
-
Signal
LB2_2 switch-on
[587]
Conditions for switching on the LB2_2.
-
-
÷
-
LB2_2
switch-
off [588]
LB2_2 switch-off: In case of a numeric signal if the signal value is lower than the
defined level.
-
-
÷
-
LB3
Group of parameters number [169]
Third logical operation setting.
MENU \ SETTINGS \ FUNCTIONS \ PLC FUNCTIONS \ LOGICAL BLOCKS \ LB3
Name [ID]
Description
Def.
LB3 Operation
Logical operation type that will be used for the logical block. Configuration possibilities OR