Rotary lobe pump
Operating instructions
VX100Q, VX136Q..QD..QDM2, VX186Q..QD..QDM2, VX230Q..QD
46/68
HiFlo
plus
HiFlo
plus-
rotary lobes, in contrast to HiFlo rotary lobes, have a second groove. The groove, which in the
“arrangement HiFlo
plus
"
is not
to be used, is marked in red.
8.7.1
Rotary lobe change - VX100Q, VX136Q, VX186Q, VX230Q series
Fig.
“Rotary lobe change, Q series"
1.
Open Q cover (5)
Chapter
"Opening the Q cover".
2.
Remove plug (7) and anti-fatigue bolts (VX136Q, VX186Q) or hexagon socket head cap screws
(VX100Q) (8) in the rotary lobes (11). Pull off the pressure disc (9) using a suitable screw (anti-fatigue
bolt, hexagon socket head cap screw) or with the threaded rod of the rotary lobe puller and remove
the spring washers (10).
With the VVA series with rubberized rotary lobes (not with solid material lobes), the rotary lobe
core is protected by an additional sealing ring in which the pressure disc and spring washers
are located. Dismount this sealing ring and reinstall it after the rotary lobe change.
3.
Pull the rotary lobes from the shafts using a rotary lobe puller (see spare parts list). With the VX230Q
series the rotary lobes can be pulled off the shafts using a commercially available universal puller with
a span width of 200 mm and a span depth of 150 mm.
Pull HiFlo- and HiFlo
plus-
rotary lobes off the upper and lower shaft in pairs.
4.
Install the new rotary lobes in reverse sequence
Fig.
"HiFlo and HiFlo
plus arrangement
".
Before installing the new rotary lobes, thoroughly clean the contact surfaces of rotary lobes and
seal components!
5.
With the VX136Q series install two spring washers per shaft, with the VX100Q, VX186Q and VX230Q
series, install one spring washer per shaft
Fig.
"Position of pressure disc and spring washers".
Make sure that the spring washers are the correct way round in the pressure disc.
Carefully press the pressure disc and spring washers into the rotary lobe groove. Spring
washers must not fall into the extracting groove.
Use the anti-fatigue bolt or hexagon socket head screw to tighten spring washers and pressure
disc
Chapter
“Tightening torques of the hexagon socket head cap screws for mounting the
pressure disc".
Install plug (7).
6.
Close Q cover
Chapter
"Closing the Q cover".
7.
Apply pressure to buffer chamber
Chapter
"Buffer chamber".
Material FPM for rotary lobes
The material 'FPM' for rotary lobes is usable only up to max. 6 bar. Please note the maximum operating
pressure
Chap.
“Technical data".
Fig.
27
: Rotary lobe change, Q series
Summary of Contents for VX Series
Page 1: ...Best Practices for Installation of VX Rotary Lobe Pumps WELCOME TO VOGELSANG FACTORY TRAINING ...
Page 15: ...Installation ...
Page 24: ...Pressurizing the Pump ...
Page 36: ...Direction of flow Startup Checklist Startup ...
Page 44: ......
Page 121: ...Service Manual Service Manual Pump Models VX Series Q Pumps ...
Page 122: ...Service Manual Service Manual Pump Models VX Series Q Pumps ...
Page 123: ...Service Manual Service Manual Pump Models VX Series Q Pumps ...