Pump Models:
VX Series Q Pumps
No Discharge
Below Capacity
Irregular Discharge
Lost Prime
Pump Stalls at Startup
Pump Overheats
Motor Overheats
Excessive Power Draw
Noise & Vibration
Pump Element Water
Excessive Seal Wear
Seizure
Causes
Solution
X
X
Metal to metal contact of
pumping element.
Check rated and duty
pressures.
X
X
Worn pumping element.
Install new components
X
X
Relief valve leakage
Adjust pressure setting.
Examine & clean seating
surfaces. Install new
components.
X
X
Relief valve chatter
Check water sealing
surfaces & guides. Install
new components.