Service Manual
Service Manual
Pump Models:
VX Series Q Pumps
Special Tool Required
Using the lobe puller, loosen the
arm bolts, and place the end of
the arms into the groove provided
in the lobe. Tighten the arm bolts
on the lobe puller. Tighten the
extraction bolt on the lobe puller
to pull the lobes from the pump.
Repeat as necessary (in the
event of “stacked” lobes),
removing lobes from both shafts
(
Fig. 9
).
Note:
Lobes must be pulled
together in pairs. Using two sets
of pullers is recommended as it
will save you a significant amount
of time.
Lobe Pullers: We recommend ordering two sets.
VX136 Short Lobe Puller: Part #PBA.B001.TK for models 70, 105
VX136 Long Lobe Puller: Part #PBA.B001.TL for models 140, 210
VX186 Short Lobe Puller: Part #PBA.A001.TK for models 92, 130,184, 260
VX186 Medium Lobe Puller: Part #PBA.A001.TL for models 184, 260
VX186 Long Lobe Puller: Part #PBA.A001.T1 for models 368, 390
Fig. 9