Service Manual
Service Manual
Pump Models:
VX Series Q Pumps
Equipment Alignment – Base plate
The base frame of motor driven units must not be out of alignment or under stress by the
mounting bolts to prevent noise and wear of coupling. After mounting, the alignment of
coupling must be checked and corrected prior to operation.
Retighten all motor and pump mounting screws on the frame
after 20 initial operating hours.
For pumps with belt drive check the belt tension as described earlier:
•
After the first 10 operating hours
•
Then every 2000 operating hours
Use the eye bolts on the pumps
only
for lifting the pump without any additional
mounting parts such as the motor.