Service Manual
Service Manual
Pump Models:
VX Series Q Pumps
Remove the case sealing o-ring
(
Fig. 50
). Vogelsang
recommends replacing this seal
whenever the case is removed,
but if it is undamaged and does
not indicate excessive
compression it may be re-used.
Drive the two shafts from the
wet-end of pump through the
gear end of pump. Use
appropriate drift and heavy
hammer as shaft is a tight fit
through the double roller bearing
(
Fig. 51
).
Note:
Provide soft landing for the
shafts as they leave the pump
body, or use a helper to hold
shafts as they are driven out of
the pump.
Fig. 50
Fig. 51