![Vogelsang VX Series Manual Download Page 105](http://html.mh-extra.com/html/vogelsang/vx-series/vx-series_manual_1044344105.webp)
Rotary lobe pump
Operating instructions
VX100Q, VX136Q..QD..QDM2, VX186Q..QD..QDM2, VX230Q..QD
61/68
12 Specifications
12.1 Material description for rotary lobes
Marking
on the rotary
lobe
Material
Elastomer-based
resistant
up to
Pump medium
Characteristics
NBR
NBR
Nitrile butadiene
rubber
80°C *
Sewage sludge,
petrol,
oil, grease, diesel oil,
spindle oil
oil-resistant
NBR
NBR, white
Nitrile butadiene
rubber
80°C *
Oil, butter, linseed
and olive oil, lard
food grade
SBR
SBR
Styrene butadiene
rubber
60°C
Liquid manure
wear-resistant
SL
EPDM-SL
(
EPDM sewage
line)
Ethylene
propylene
diene M-class
rubber
80°C *
Water, liquid manure,
sewage sludge,
biogas substrate
not oil and grease-
resistant,
water-resistant,
steam-resistant
AL
EPDM-AL
(
EPDM-Aqua-
Line)
Ethylene
propylene
diene M-class
rubber
80°C *
Drinking water
Drinking water
approved **,
not oil or grease-
resistant,
water-resistant,
steam-resistant
EPDM
EPDM, white
Ethylene
propylene
diene M-class
rubber
80°C *
Water, mash, slightly
acidic products
food grade
PU
PU
(Werobust)
Polyurethane
vulcanised
50°C
abrasive medium
wear-resistant
PUR
PUR
Polyurethane
cast
80°C
abrasive medium
highly wear-resistant
CSM
CSM
(Hypalon)
Chloro-sulfonyl
polyethylene
rubber
80°C *
Petrol, oil, acids,
alkali solutions
wear-resistant,
acid-resistant and
alkali-resistant
FPM
FPM
Fluorocarbon
gum
80°C *
Solvents, salt water,
oil, petrol, acids
acid-resistant and
alkali-resistant
Steel lobes
(solid material)
1.4571
150°C
200°C*
pure medium
Chemistry
high temperatures,
high chemical
resistance
Steel lobes
(solid material)
C45 nitrided
150°C
200°C*
pure medium
petrochemical
high temperatures,
chemical resistance
*
consult Vogelsang in the event of the combination of "high pressure and high temperatures"
** drinking water approvals: KTW, DVGW-Arbeitsblatt, W 270, WRAS, BELAQUA
Please consult us
if you require combinations with high pressure and high temperatures, see * in table
with solid material lobes with media containing foreign matter
if you should discover discrepancies or if precise media data has not been provided
Material FPM for rotary lobes
The material 'FPM' for rotary lobes is usable only up to max. 6 bar. Please note the maximum operating
pressure
Chap.
“Technical data".
Summary of Contents for VX Series
Page 1: ...Best Practices for Installation of VX Rotary Lobe Pumps WELCOME TO VOGELSANG FACTORY TRAINING ...
Page 15: ...Installation ...
Page 24: ...Pressurizing the Pump ...
Page 36: ...Direction of flow Startup Checklist Startup ...
Page 44: ......
Page 121: ...Service Manual Service Manual Pump Models VX Series Q Pumps ...
Page 122: ...Service Manual Service Manual Pump Models VX Series Q Pumps ...
Page 123: ...Service Manual Service Manual Pump Models VX Series Q Pumps ...