Eccellenza Café – Service Manual
August 5, 2013
83
Circuit Breakers (5 Amp)
a.
Disconnect the wiring from the circuit breaker.
b.
Loosen the plastic hex nut that secures the breaker to the main power plate.
c.
Remove the breaker and replace it with the new one.
d.
Secure the breaker to the main power plate with the hex nut.
e.
Connect the wiring to the new circuit breaker.
Fuse Holder (15 Amp)
a.
Disconnect the wiring from the fuse holder.
b.
Loosen the plastic hex nut that secures the fuse holder to the main power
plate.
c.
Remove the fuse holder and replace it with the new one.
d.
Transfer the fuse and the cap from the old fuse holder onto the new one (if
required).
e.
Install the new fuse holder and secure it to the main power plate with the hex
nut.
f.
Connect the wiring to the new fuse holder.
Main Power Switch
a.
Disconnect the wiring from the main power switch.
b.
Compress the clips on each side of the switch, and push it through the main
power plate.
c.
Insert the new switch into the cutout on the main power plate, and snap it in
place to secure it.
d.
Connect the wiring to the new power switch.
i.
Black wires (hot) -> connect to tabs #1 and #1a on the switch.
ii.
White wire (neutral) - dual terminal -> connects to tab #2a on the switch.
iii.
White wire (neutral) -> connects to tab #2 on the switch
Service Cord Power Plug
a.
Disconnect the service cord from the power plug on the main power plate.
b.
Disconnect the wiring at the rear of the power plug.
c.
Remove the two screws securing the plug to the main power plate and remove
the plug.
d.
Insert the new plug onto the plate and secure it in place with two screws.
e.
Reconnect the wiring to the rear of the power plug.
i.
Black wire (hot) –> connects to the left tab.
ii.
White wire (neutral) -> connects to the right tab.
iii.
Green/Yellow wire (ground) -> connects to the bottom tab.