Summary of Contents for "I" Series 227

Page 1: ... INSTRUCTIONS THIS DOCUMENT CONTAINS IMPORTANT INFORMATION This Manual must be read and understood before installing or operating this equipment Part No 630460042INS Release Date October 27 2003 Revision Date May 06 2014 Revision C CORNELIUS INC 2003 2014 PRINTED IN U S A ...

Page 2: ...TRUCTIONS 2 LOCATION OF EQUIPMENT 2 PLUMBING CONNECTIONS 2 ELECTRICAL 4 INSTALLATION CHECK POINTS 4 START UP AND CHECK OUT 5 OWNER OPERATOR 6 CLEANING PROCEDURES 6 PREP CLEANING 6 CLEANING THE WATER SYSTEM EVAPORATOR 6 SANITIZING PROCEDURES 7 DUMP CYCLE 8 ADJUSTING BRIDGE THICKNESS 10 TOTAL ICE CAPACITY 10 ...

Page 3: ...after delivery 3 Should concealed damage be found when product is unpacked retain the packing material and the product and request an inspection from the deliverer 4 All claims for loss or damage should be filed at once Delays in filing will reduce the chance of achieving a satisfactory resolution to the claim SPECIFICATIONS ICE CUBER The following table contains equipment specification informatio...

Page 4: ...tion of your product ever be exposed to freezing temperatures it must be shut down and winterized FIGURE 1 INSTALLATION PLUMBING CONNECTIONS 1 All plumbing lines and connections must conform to local and national plumbing codes 2 Line shut off valves must be located in supply water lines for cuber and condenser if product is wa ter cooled Water supply to water cooled condenser must include a stand...

Page 5: ...0 5 Á Á Á 2 06 IWCS 227 REAR VIEW Á Á 8 75 Á Á Á 2 25 1 ELECTRICAL CORD ATTACHED 20 AMP CIRCUIT 2 3 4 DRAIN TUBING SIZE 5 8 I D 3 3 8 RESERVOIR WATER INLET SAE MALE FLARE 4 3 4 BIN DRAIN STD PIPE SAE 5 5 8 CONDENSER WATER OUTLET MALE FLARE 6 5 8 CONDENSER WATER INLET MALE FLARE 1 ELECTRICAL CORD ATTACHED 20 AMP CIRCUIT 2 3 4 DRAIN TUBING SIZE 5 8 I D 3 3 8 WATER INLET SEA MALE FLARE 4 3 4 BIN DRAI...

Page 6: ...and sanitized 2 Does electrical and plumbing meet code requirements 3 Check correct operating water level in the water pan OPERATING WATER LEVEL SINGLE EVAPORATOR WATER PAN RIGHT SIDE VIEW ÎÎÎÎ ÎÎÎÎ ÎÎÎÎ ÎÎÎÎ ÎÎÎÎ 2 38 FIGURE 3 SINGLE EVAPORATOR WATER LEVEL 4 If water cooled are inlet and drain connections to condenser correct to prevent water hammer 5 Are drain lines separate and vented 6 Is ther...

Page 7: ...ill operate when the evaporator cools to 25_F 3 9_C De press the manual harvest switch located on the circuit board The fan motor will stop and the water dump valve will open In 3 seconds the hot gas solenoid will open and 15 seconds after depressing the manual harvest switch the water pump will stop and the dump valve will close terminating the dump cycle 3 Hold the water curtain open for a maxim...

Page 8: ...When using any chemical rubber gloves and eye protection should be worn PREP CLEANING Use full strength ice machine cleaner on a coarse surface cloth material such as terry cloth and wipe down the inside wall of the evaporator area the water pan the water curtain and evaporator plastic extru sions If the water distributor tube has heavy scale build up remove and soak it in full strength ice ma chi...

Page 9: ...CEDURES NOTE To be performed only after cleaning the ice machine 1 Add 1 4 ounce 7 08 g sodium hypochlorite solution common liquid laundry bleach to the water pan and allow the pump to circulate the solution for 5 minutes You may also use a commercial sani tizer such as Calgon Ice Machine Sanitizer following the directions on the product label 2 Turn the product power switch off and depress the du...

Page 10: ...h cycle S every 7th cycle Remember the higher the mineral content in the water supply the more often it will be required to dump the water and or clean the product if proper water treatment is not used Transformer RD Error OFF OFF OFF ON ON ON SW4 SW4 SW4 5 6 YL YL YL YL S3 1 S3 2 OFF ON GR Comp Micro Processor 4 Curtain Switch Connected To Any Bin Connector J4 J7 FACTORY SETTING AS RECEIVED Sucti...

Page 11: ...9 ...

Page 12: ...ocated on the circuit board as follows 1 Thinner Bridge turn the ice thickness pot adjustment screw CW one full turn Allow two cycles before determining if additional adjustments are required 2 Thicker Bridge turn the ice thickness pot adjusting screw CCW one full turn Allow two cycles before determining if additional adjustments are required NOTE Never judge the thickness of the ice from the firs...

Page 13: ...www cornelius com CORNELIUS INC ...