Eccellenza Café – Service Manual
August 5, 2013
55
10.
Remove the Oetiker clamp and disconnect the inlet hose from the inlet fitting at
the bottom of the water tank.
11.
Disconnect the wiring from the components at the top of the water tank (on the
tank lid).
a.
Two heater element power wires.
b.
Thermal cut-off switch wire.
c.
Three level probe wires.
d.
Inline connector on the temperature probe.
12.
Lift the water tank up and out of the machine.
To re-install the hot water tank, follow these same instructions, but in the reverse
order.