6.
Remove the pump inlet tube from the flavoring bottle and disconnect the pump
outlet tube by pulling it off from its spout on the spout support plate.
7.
Remove the convoluted tubing installed around the flavoring tubes. It may be
necessary to cut any tape or cable ties securing the three tubes together.
8.
Remove the flavor pump (the flavor 2 pump is used as an example).
a.
Loosen the two screws that secure the pump to the door.
b.
Lift the pump until it clears the two screws, and remove it.
NOTE: When removing the flavoring tubes, have a paper towel ready as
flavoring will drip out of the ends of the tubing. It is possible that the flavoring
can stain clothing or other surfaces on which it drips.