Eccellenza Café – Service Manual
August 5, 2013
57
5.
Disconnect the wiring from the valve(s) to be replaced.
6.
Pull the valve(s) from the silicone seal support in which it is mounted. Use
caution as there may still be a bit water remaining behind the valve
when you remove it – this water may be extremely hot.
O
UTLET
V
ALVE
W
IRING
C
ONNECTIONS
Coffee Valve
Red Wires
Powder Valve
White Wires
Hot Water Valve
Yellow Wires
To re-install an outlet valve, follow these same instructions, but in the reverse
order.
NOTE: If the coffee valve is replaced, it may be necessary to adjust the valve’s
flow rate by using the restrictor at the front of the valve. To decrease the flow,
turn the restrictor clockwise. To increase the flow, turn it counter-clockwise.