Eccellenza Café – Service Manual
106
August 5, 2013
MESSAGE DISPLAYED
CAUSE
POSSIBLE REMEDIES
Factory Settings Version
Error
The version of Factory
Settings is not compatible
with the machine model.
•
The Factory settings file you are
attempting to load is not the correct version
for the firmware in the machine. Load the
proper version of the Factory Settings file.
Filling Water Tank
The water tank is filling.
•
Normal operating message and does
not indicate an error.
Finding Brewer Home
Brewer is cycling to find the
home (starting) position.
•
Normal operating message and does
not indicate an error.
Heating Water
Water inside the hot water
tank is heating.
•
Normal operating message and does
not indicate an error.
LCD Error
An error has been detected
with the LCD display.
•
Verify the wiring connections to the LCD
display.
•
Replace the LCD display.
Money System Error
The coin changer or bill
acceptor is not being
detected.
•
Verify the wiring connections at the
control board and inside the changer unit.
•
Replace the defective coin changer or
bill acceptor.
Overflow Error
A water overflow has been
detected.
•
Empty and dry the overflow/cup tray.
•
Verify the water level probe adjustment.
They may be set too high allowing too
much water into the tank.
•
Water level probes may need to be
cleaned.
•
Inlet valve may be leaking, constantly
allowing water to enter the tank. Replace
the inlet valve.
•
The water in the tank may be
overheating. Lower the water temperature
setting.
Overheat Error
The water tank is
overheating.
•
Check the temperature settings in the
set-up.
•
The temperature probe may need to be
replaced.
PnB not Detected
The control board is not
being detected.
•
The USB cable is not connected to the
control board or the expansion board.
Verify the connections.
Port J10 Not Detected
Wiring harness is
disconnected from port 10
on the control board.
•
Reconnect the wiring harness to port 10
on the control board.
Port J23 Not Detected
Wiring harness is
disconnected from port 23
on the control board.
•
Reconnect the wiring harness to port 23
on the control board.
Press Start to Find
Brewer Home
The brewer is not in the
home (starting) position.
•
Press "
START
" (the
TEXT BOX
at the top of
the screen) to cycle the brewer.
•
If the brewer cannot detect the home
position, check the brewer home switch &
wiring, the brewer motor, and the brewer.