WARNING!
When plugging SIREN & ZONE terminals
back into place, be sure to align them carefully with the
pins on the PCB. Misaligned or reverse insertion of
terminals may damage internal PowerMax10-G2 circuits!
3.4 Extension Modules Installation
3.4.1 GSM Installation
The internal GSM 350 module enables the PowerMax10-
G2 system to operate over a GSM/GPRS cellular network
(for further details, see the GSM 350 PG2 Installation
Instructions).
The GSM modem auto detection feature enables
automatic enrollment of the GSM modem into the
PowerMax10-G2 control panel memory. GSM modem auto
detection is activated in one of two ways: after tamper
restore and after reset (power-up or after exiting the
installer menu). This causes the PowerMax10-G2 to
automatically scan GSM COM ports for the presence of
the GSM modem.
In the event that the GSM modem auto detection fails and
the modem was previously enrolled in the PowerMax10-
G2 control panel, the message "Cel Rmvd Cnfrm" will be
displayed. This message will disappear from the display
only after the user presses the
OK
I
button. The modem
is then considered as not enrolled and no GSM trouble
message will be displayed.
Note:
A message is displayed only when the
PowerMax10-G2 alarm system is disarmed
.
3.4.2 PowerLink Installation
The PowerLink module enables viewing the PowerMax10-
G2 system over the internet (for further details, see the
PLINK PRO Installation Instructions).
The Broadband Module modem auto detection feature
enables automatic enrollment of the Broadband Module
modem into the PowerMax10-G2 control panel memory.
Broadband Module modem auto detection is activated in
one of two ways: after tamper restore and after reset
(power-up or after exiting the installer menu). This causes
the PowerMax10-G2 to automatically scan the Broadband
Module COM ports for the presence of the Broadband
Module modem.
In the event that the Broadband Module modem auto
detection fails and the modem was previously enrolled in the
PowerMax10-G2 control panel, the message "BBA Remvd
Cnfrm" will be displayed. This message will disappear from
the display only after the user presses the
OK
I
button.
The modem is then considered as not enrolled and no
Broadband Module trouble message will be displayed.
Notes:
A message is displayed only when the PowerMax10-G2
alarm system is disarmed.
In the event of a power failure the Broadband Module will
not operate. Power (AC or battery) must be disconnected
from the circuit before connecting / disconnecting the
Broadband Module.
3.5 Closing the Control Panel
Control panel final closure is shown below.
1
To Close the Control Panel:
1.
Close the front cover
2.
Fasten the screws
Figure 3.4
- Final Closure