G4 Multi Channel Weighing Instrument
8-3
Fieldbus
Shows the fieldbus type, address and status of the optional Fieldbus interface.
It also gives the possibility to study the contents in selected parts of the instrument
memory (data to and from the fieldbus master). The function is very useful for
advanced fault finding in case of problems with the fieldbus communication.
The contents of the output memory (data
to
the fieldbus master) are displayed in
hexadecimal form with two lines on the display. On each line four byte values are
displayed, preceded by 'o' for output and the address of the first byte.
The contents of the input memory (data
from
the fieldbus master) are displayed in
hexadecimal form with two lines on the display. On each line eight byte values are
displayed, preceded by 'i' for input and the address of the first byte.
The ‘+’ and ‘
−
’ keys are used to step forwards /
backwards in the memory.
Use key ‘
↵
’ to change between display of output and input
memory.
When entering the fieldbus menu is a line showing
fieldbus type and address shown. Press the ‘+’ key to
display the fieldbus status. Press ‘+’ key again and
memory data will be shown. Press the ‘
↑
’ key to leave
fieldbus menu.
See chapter ‘Communication’ section ‘Fieldbus and
EtherNet/IP Data Definitions’ for details on fieldbus data
mapping.
The figure on the right shows some examples of how the
fieldbus diagnostics display might look.
EtherNet/IP
The menu give the possibility to study the contents in used instances (data to or from
the scanner). The function is very useful for advanced fault finding in case of problems
with the communication.
The content in the selected instance are displayed in hexadecimal form with two lines
on the display. On each line four byte values are displayed, preceded by the address of
the first byte. For producing instances 102 and 103 the amount of data is according to
the actual number of data blocks used (setup).
The first screen show selected instance. If a scanner is connected to the shown
instance Active is show else is Inactive shown. No data is shown if the instance is
inactive.
The ‘+’ and ‘
−
’ keys are used to step the displayed
addresses forwards / backwards.
Use key ‘
↵
’ to’ to display next instance (100 – 101 –
102 – 103 – 100 etc).
See chapter ‘Communication’ section ‘Fieldbus and
EtherNet/IP Data Definitions’ for details on fieldbus
data mapping.
o000 00 00 00 02
o004 00 00 9C 41
i000 00 00 00 00
i004 00 00 00 00
Fieldbus, Adr.
Profibus, 6
Fieldbus Status
Active
Fieldbus diagnostics.
000 00 00 00 02
004 00 00 9C 41
EtherNet/IP
I:103 Active
EtherNet/IP diagnostik
Summary of Contents for G4
Page 2: ......
Page 18: ...Technical Manual 1 14 ...
Page 39: ...G4 Multi Channel Weighing Instrument 3 7 ...
Page 104: ...Technical Manual 5 18 ...
Page 158: ...Technical Manual 6 54 ...
Page 178: ...Technical Manual 7 20 ...
Page 186: ...Technical Manual 8 8 ...
Page 196: ......
Page 197: ...G4 Multi Channel Weighing Instrument Appendix 1 ...
Page 198: ...Technical Manual ...
Page 199: ......