Technical Manual
6-16
Accumulated weight registers
Accumulated weights are updated when a print command is issued. The accumulated
values can also be read in the ‘Accumulated Weights’ menu in the ‘Main menu’. In this
menu it is also possible to zero or set the values.
There is also a set of registers that contain the Batched Weights, which are
accumulated weights automatically calculated during batching. See the separate
description ‘Scale Batching Program Option’ ‘Technical Manual Supplement’.
Data type: Integer
Explanation Scale number
No of R/W
1
2
3
4
5
6
7
8
reg
LOW
42250 42256 42262 42268 42274 42280 42286 42292 3
R
HIGH
42253 42259 42265 42271 42277 42283 42289 42295 3
R
Data type: Float
Explanation
Scale number
No of R/W
1
2
3
4
5
6
7
8
reg
LOW
46200 46204 46208 46212 46216 46220 46224 46228 2
R
HIGH
46202 46206 46210 46214 46218 46222 46226 46230 2
R
An accumulated weight is represented by two values (HIGH, LOW). To get the
resulting value multiply value HIGH by 10000 and add value LOW. LOW is a value
between
±
9999.999 with 3 decimals. HIGH is a value without decimals between
±
999999. To zero accumulated weight, send 0 to both HIGH and LOW.
NOTE! Both HIGH and LOW must be written in ONE Modbus message on order to
change the value.
Summary of Contents for G4
Page 2: ......
Page 18: ...Technical Manual 1 14 ...
Page 39: ...G4 Multi Channel Weighing Instrument 3 7 ...
Page 104: ...Technical Manual 5 18 ...
Page 158: ...Technical Manual 6 54 ...
Page 178: ...Technical Manual 7 20 ...
Page 186: ...Technical Manual 8 8 ...
Page 196: ......
Page 197: ...G4 Multi Channel Weighing Instrument Appendix 1 ...
Page 198: ...Technical Manual ...
Page 199: ......