Chapter 3 - 7700 Flash Storage Platform Device Configuration
58
7700 Flash Storage Platform Installation Guide 7.6.3.x
530-0267-00 Rev 02
To preconfigure IPMI/iDRAC to access the Concerto OS Quick Start configuration utility via a Virtual
Console, perform the following:
1.
Connect a VGA monitor and USB keyboard to the front or rear panel VGA and USB ports.
2.
Power on to boot the 7700 FSP Controller.
3.
Carefully monitor the POST and after the initial setup and firmware initialization, press
F2
to
access System BIOS and Settings on the 7700 FSP Controller.
4.
Navigate to the IMPMI/iDRAC Settings and iPMI/iDRAC Network Settings.
5.
Modify the current default IPv4 settings for the IPMI/iDRAC (192.168.0.120), and reset this IP
address to your desired IP address (either as a static or as a DHCP client and record this new
IP address).
Factory default values for IPMI/iDRAC: IP Address (192.168.0.120), Subnet Mask
(255.255.255.0), and Gateway (192.168.0.2).
6.
Press
Esc
to exit the navigation.
7.
Accept the new settings and allow the 7700 FSP Controller to reboot.
The 7700 FSP Controller is now accessible via the Virtual Console at https://<
IPMI/iDRAC IP
address
>.
8.
Browse to the assigned IP address to access the iDRAC Management interface using the
IPMI/iDRAC Virtual Console (using https://<
IPMI/iDRAC IP address
>).
9.
Accept all security warnings to use the iDRAC unregistered SSL certificate at first connection.
10.
At the iDRAC Web logging screen, type in the username and password (Violin default values
are "
admin
" and "
violin101
"), and click
Submit
.