Configuring the 7000 Series FSP
530-0267-00 Rev 02
7700 Series Flash Storage Platform Installation Guide 7.6.3.x
97
To describe the alert e-mail configuration, specify:
Run the following to verify that callhome is set up properly:
For specific details about manually configuring the Memory Gateways (MG-A and MG-B) in a 7000
Series FSP shelf, see
Configuring the Memory Gateways
on page 94, or see the setup and
configuration methods in the latest version
Violin 7000 Series Flash Storage Platform Installation
Guide
. If you encounter any issues with configuring or accessing a Memory Gateway, see
Troubleshooting Memory Gateways
on page 112 for details.
Completing the ACM Configuration
Log in to the Master ACM and then issue the following commands:
Where:
“array serial-logging all-mgs”
enables serial logging on the Memory Gateways. This
feature is disabled by default.
-mf (--email-from), -mt (--email-to) and -ms (--email-subject), which
represent 'from', 'to' and 'subject' fields of the alert email
respectively.
-ai (--alert-interval) is an required parameter which specifies the
interval for alert email to be received. It has following format:
DD:HH:MM, meaning the interval unit of Day:Hour:Minute.
-al (--alert-level) is an option to filter server events. Through this
option, you can select events to be received based on event severity
level.
The legal values to the options are:
None: no alert email will be received;
Critical: only Critical events will be received;
Error: only events with severity Error and above will be received;
Warning: only events with severity Warning and above will be received;
Information: events with level Information and above will be received.
# /usr/local/concerto/bin/test_mail <
customer-mail-
relay_hostname_or_IP>
<
customer_email_address
(config) #
array serial-logging all-mgs
(config) #
write memory