Appendix A - System Reference
100
7700 Series Flash Storage Platform Installation Guide 7.6.3.x
530-0267-00 Rev 02
Note:
A 7000 Series FSP with 32 VIMM will have a different number of partitions.
7.
Issue the following commands to read the new partitions created by the “
media_init
”
command into the configuration file:
8.
Log in to Memory Gateway B and then issue the same commands:
9.
Start a terminal session to the Master ACM, and then type the following commands to enter
configuration mode:
10.
Enter the following commands to power down both Memory Gateways:
11.
Once both Memory Gateways are powered down, restart them one at a time, as follows:
[root@
hostname
-MG-A ~]#
concerto stop all
[root@
hostname
-MG-A ~]#
concerto setup
Concerto Block Device Module [ OK ]
Violin Systems Concerto Server v7.6.3.1 - (Build 9271) Setup
WARNING: Configuration file already exists: /usr/local/concerto/etc/
[hostname-mg-x]/ipstor.conf
Overwrite? (y/n)
Y
[root@
hostname
-MG-B ~]#
concerto stop all
Violin Concerto Server version 7.6.3.1 (Build 9271)
Copyright (c) 2017-2018 Violin Systems LLC. All Rights Reserved.
All virtual devices are going to be detached.
We recommend stopping all Concerto client services prior to shutdown.
Otherwise, data loss may occur.
Are you sure you want to continue? (y/n) [n]: y
Continue with detaching all virtual devices
[root@
hostname
-MG-B ~]#
concerto setup
Concerto Block Device Module [ OK ]
Violin Systems Concerto Server v7.6.3.1 (Build 9271) Setup
WARNING: Configuration file already exists: /usr/local/concerto/etc/
[hostname-mg-x]/ipstor.conf
Overwrite? (y/n)
Y
violin-acma [violin: master] >
enable
violin-acma [violin: master] #
configure terminal
(config) #
no array module type mg enable
WARNING: Powering down array module(s) may cause data disruption. Are
you sure? [no]
yes
(config) #
array module id mg-a enable
.
Power-on completed successfully.
.
(config) #
array module id mg-b enable
.
Power-on completed successfully.