Configuring Storage
530-0267-00 Rev 02
7700 Series Flash Storage Platform Installation Guide 7.6.3.x
101
12.
Type the following command to verify that both Memory Gateways are up and running and
that the IP addresses are assigned:
Allocating the Storage Space
Follow the steps in this section to allocate the storage to both Memory Gateways. You will be
creating two storage pools: one for Memory Gateway A and one for Memory Gateway B.
Note:
Only one storage pool is allowed to be created on a Memory Gateway.
1.
Using its IP address, connect directly to Memory Gateway A.
2.
Log in to Memory Gateway A:
•
User name:
root
•
Password:
<password>
3.
Once logged in, type the “
concerto status
” command to verify that the Memory Gateway
is up and running and that all modules show a status of “[RUNNING]”:
4.
Type the following command to display all of the storage devices created on the 7000 Series
FSP:
(config) #
show array module type mg detail
[root@
hostname
-MG-A ~]#
concerto status
Violin Concerto Server version 7.6.3.1 (Build 9271)
Copyright (c) 2017-2018 Violin Systems LLC. All Rights Reserved.
Status of Concerto FC Initiator Module [RUNNING]
...
[root@
hostname
-MG-A ~]#
isscli getpdevinfo -F