![Viessmann VH3 Installation And Service Instructions For Contractors Download Page 34](http://html.mh-extra.com/html/viessmann/vh3/vh3_installation-and-service-instructions-for-contractors_1016944034.webp)
34
Connections
for
Connection numbers on HKK
Sensor connections
A
HK
301, 302, 303
TWE
302, 303
SOL
303 (collector) + 304 (lower TWE)
Pump connections
B
Mechanical cleaning, electrostatic precipitator
B
HK
310, 320, 330
TWE
320, 330
SOL
330
Mechanical cleaning
Electrostatic precipita-
tor
(optional)
330
Mixer motor connections
C
Circulation pump connections
C
DHW circulation pump connections
C
Solar diverter valve
C
Power supply to electrostatic precipitator
C
HK
311, 321, 331
UP
321, 331
(Always connect UP to Y1)
ZP
321, 331
(Always connect ZP to Y2)
SOL
331
Power supply
Electrostatic precipita-
tor
(optional)
331
Extension kits (KM-BUS)
Max. 3 extension kits
can be connected to the boiler
control unit. Each extension kit must be connected to
the KSK PCB via KM-BUS.
Installation sequence
Electrical connections
(cont.)
5679249