PYROMAT DYN45 - DYN85 Issue 1.0
Page 27 of 72
Screen
number
Parameters
Factory setting
39
Pause in extraction system 2:
Clock circuit pause time for extraction system 2
(e.g. spring core extractor, ascending
extractor,... )
0s
40
Extraction system 1, hydraulics, delay time:
Set switch-on delay of hydraulic drive extraction
system 1.
5s
41
Extraction system 2, hydraulics, delay time:
Set switch-on delay of hydraulic drive extraction
system 2.
5s
50 Silo
filling:
Starts the silo filling function.
L
The function only becomes available once
the boiler has been out of operation for at
least one hour.
No
5.5 Keys F5 to F8 "Extended control system"
Your ECOTRONIC is extended with a multitude of heating controllers such as, e.g. heat
consumers, auxiliary heat generators, solar energy.
The operation of the external controllers is carried out principally on the heating system
control module.
L
The extended control systems are assigned to keys F5 to F8 as per the wishes of
the customer. Each extended control system is assigned to a separate key.
L
Information regarding the extended control system can be found in chapter
"ECOTRONIC control system extensions".